Sauna sizes · feet

What size heater for a 5×7 ft sauna?

A 5×7 ft room with a 7 ft ceiling holds 245 cubic feet. Glass and wall construction change the heater size more than the floor area does.

About a 6 kW heater with a standard glass door. Glass, log walls or an outdoor location change that, as the table shows.

Heater size by door, glass and walls

The table runs three common sizing rules on the same room. The recommendation is the smallest standard size that reaches the middle result. The highlighted row is the answer above.

Room setupCalc. volumeNordicSurfaceUSPickWarm-up
Insulated, solid wood door245 ft³6 kW6 kW6 kW6 kW63 min
Insulated, glass door304 ft³6 kW6 kW8 kW6 kW62 min
Glass door + window343 ft³8 kW8 kW8 kW8 kW43 min
Full glass front (5 ft wall)383 ft³8 kW8 kW9 kW8 kW42 min
Solid log walls, glass door456 ft³9 kW18 kW8 kW9 kW40 min
Outdoor, insulated, glass door304 ft³6 kW6 kW8 kW6 kW81 min

Heaters rated for this room

These models list a rated room range that covers 304 ft³, the calculated volume with a glass door.

Electrical supply

A 6 kW heater draws about 25.0 A at 240 V, 26.1 A at 230 V single-phase or 8.7 A per phase at 400 V three-phase. The heater manual and a licensed electrician set the breaker and cable size.

Common questions

What size heater do I need for a 5×7 ft sauna?

With a standard glass door, a 5×7 ft sauna (245 ft³) needs about a 6 kW electric heater. Choose a model whose rated room range includes the calculated volume of 304 ft³.

Why do sauna heater calculators give different answers?

Manufacturers count glass, masonry and uninsulated walls differently. Harvia adds 1.2 m³ per m² of cold surface, HUUM adds 1 m³ per m² but also counts uninsulated walls in full, and US retailers use about 1 kW per 50 ft³ plus extra for glass.

How long does a 6 kW heater take to warm a 5×7 ft sauna?

About 62 min from 20 °C to 80 °C (68 °F to 176 °F), depending on stone load, ventilation and how cold the walls are.